SERVICE CAPABILITY

We Don't Stop at Delivery.

Manufacturing a transformer is where our responsibility begins not where it ends. KLR Transformers provides the full range of field services needed to keep transformers of any make operating reliably across their entire working life.

Structured, scheduled maintenance programmes that keep critical transformers inspected, tested, and documented reducing the risk of unplanned failure and extending operational life.

✓  Scheduled site visits  1, 2, or 4 per year to requirement

✓  Oil sampling and BDV testing

✓  Insulation resistance (IR) and winding resistance measurement

✓  Silica gel breather inspection and replacement

✓  Buchholz relay, pressure relief, and gauge checks

✓  Maintenance history log maintained per unit

✓  Priority emergency response for AMC contract holders

Transformer oil degrades over time through moisture absorption, oxidation, and particle contamination. Our mobile oil filtration service restores dielectric strength on-site without removing the transformer from service.

✓ Hot oil circulation filtration removes moisture and particles

✓ Vacuum oil filtration moisture extraction under vacuum

✓ BDV improvement raising breakdown voltage to target specification

✓ Oil moisture content measurement before and after treatment

✓ Oil acidity and dissolved gas analysis (DGA) sampling

✓ Top-up with treated, tested oil to correct level

✓ Treatment report issued with before/after BDV readings

Factory-trained engineers deployed to site for fault diagnosis, repair, and restoration of transformers of any make and any capacity with fast response and comprehensive on-site capability.

✓  Fault diagnosis and root cause analysis

✓  Bushing replacement  LV and HV, all types

✓  Gasket replacement and oil leak repair

✓  Tap changer inspection, adjustment, and repair

✓  On-site winding repair where structurally feasible

✓  Oil filtration and top-up as part of repair scope

✓  Post-repair testing  IR, BDV, ratio, and polarity checks

✓  Commissioning support after repair completion

When a transformer’s performance degrades below acceptable levels, full reconditioning restores it to near-original specification extending operational life significantly at a fraction of new unit replacement cost.

✓  Full disassembly, inspection, and condition assessment

✓  Core inspection  lamination integrity and joint condition

✓  Winding assessment  resistance, IR, and turns ratio measurement

✓  Rewinding where conductor or insulation is beyond repair

✓  Insulation refurbishment  paper and pressboard replacement

✓  Tank and radiator rehabilitation  cleaning, repainting, leak repair

✓  Vapour Phase Drying (VPD) after rewinding

✓  Vacuum oil filling with fresh, tested transformer oil

✓  Complete retesting to original specification parameters

✓  Reconditioned unit report with before/after performance data

Independent testing and commissioning services for transformers of all makes verifying performance before energisation, after repair, and as part of regular condition monitoring programmes.

✓  Pre-commissioning testing  new units before first energisation

✓  Post-repair acceptance testing after service or repair

✓  Routine condition-based testing  IR, BDV, winding resistance

✓  Voltage ratio and polarity verification

✓  On-load tap changer (OLTC) performance testing

✓  Dissolved gas analysis (DGA)  incipient fault detection

✓  Partial discharge (PD) measurement  available on request

✓  Compliance testing  BIS, IEC, and ANSI standards as required

✓  Third-party witnessed testing  certified inspector attendance

✓  Test report issued with all measurements and pass/fail status

Critical spare parts for KLR-manufactured transformers and compatible replacements for other makes reducing lead times for planned maintenance and emergency repair.

✓ HV and LV bushings porcelain and oil-filled types

✓ Tap changers OLTC and OCTC types, major brands

✓ Buchholz relays and pressure relief devices

✓ Winding temperature indicators (WTI) and oil temperature indicators (OTI)

✓ Conservator tanks and drain valves

✓ Radiators and cooling fans

✓ Gaskets and sealing sets all flange sizes

✓ Transformer oil new and reclaimed, tested stock

✓ Silica gel breathers and oil level indicators

✓ Available for KLR units and third-party makes on enquiry